Weigh Bridge
Steel Pit type Weighbridges:Suitable for use in areas of limited space, the PIT weighbridge is constructed with two main longitudinal steel I-Beams that are braced very rigidly with more smaller I-Beams transversely bearing I beam sections in adequate nos. and finally topped up with MS plates to complete the structure suitable for permanent type installations .Ground level deck provides safe access for trucks and personnel.
Design Structure:Complete all Steel structure, fabricated to form a box type squarish grid network in semi bolted construction covered with M.S. Plates duly ribbed, a rugged cubical web unique modular design. The modules consists of Steel deep section main "I" Beams, which are placed longitudinally in the direction of the traffic, which take the real weight. The load cells are mounted under these main beams. Cross 'I' beam modules are bolted / welded crosswise, carefully fabricated in rigid box type grid work to prevent deflection and distortion, even on overloads. Retrofit cubical web design is symmetrical axle load bearing, where the deck plate acts as a surface skin rather than part of the load bearing structure underneath. The sophisticated design is unmatched performance that others can only hope to emulate.
Minimum Order Quantity: 1
1 Pack contains : 1 Unit
Specifications – PIT Type WeighBridge
Standard Sizes |
Platform Size | Available Capacities | LOADCELL | PRICE IN LAKH APPROX* | 7.5m x 3m | 30 MT – 50 MT | 4 | 3.75* TO 4.20* | 9 M x 3m | 30 MT – 60 MT | 4 | 5.40* TO 6.10* | 12M x 3m | 50 MT – 60 MT | 6 | 6.50* TO 7.20* | 14M X 3M | 50 MT – 80MT | 6 | 7.30* TO 7.70* | 16m x 3m | 50 MT – 100MT | 8 | 8.50* TO 9.40* | 18M x 3m | 50 MT – 100 MT | 8 | 9.20* TO 9.90* | 20M X 3M | ALSO AVAILABLE |
|
| SPECIFICATION SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Load cell type | “KELI” / “ZEMIC” BRAND Cup & Ball Type Shear Beam Loadcell Protection class | IP – 67 | Load cell output | 2 mv/v | Load cell cable | 10 / 15 / 18 meters standard. | Nos. of Load Cells | 4 / 6 / 8 / 10 nos. |
|
Girders / “I” Beam | Main Beam – 5 / 6 Nos. of Weigh bridge Length Cross Beam – 2 Nos. of Weigh bridge Width |
Top Plate | 8 / 10 / 12 mm MS Plain Top Plate with 12 mm Ribbed design |
Foundation | Based on RCC raft and side. Brick walls saving 40% construction costs and time |
Foundation parts | Modular cubical web bolting design, Special non-shrinking grouting materials used which are re- usable in relocations |
Readability | 5 / 10 / 20 Kg. |
IT – Unit | Alpha Numeric Digitizer, with 1530 records memory, RS-232 Computer Interface |
Mounting system | Self existing mounting using Self aligned loading |
Safe loads Strength & safety | 100% on dead load Overload protection : 150% static load load structural overload: 300% static load |
Side Rail Kerbing | Optional in either side for vehicle guidance & safety |
Installation | Fastest installation and easy relocation due to retrofit semi-bolted construction |
CHARGES | INSTALLATION, LEGAL METROLOGY DIVISION STAMPING AND TRANSPORTATION CHARGES WITH TAX ARE EXTRA. |
IMAGES , SIZE AND SPECIFICATIONS ARE DIFF. AS PER PRODUCT MODELS. Price will be change without notice. |